Type S NEMA motor starters are used for full voltage starting and stopping of AC squirrel cage motors. Type S motor starters have ratings up to 810 amperes. This 3 pole NEMA Size 0 non-reversing starter has an 18 ampere rating. NEMA Size 0 motor starters have 3 phase ratings of 3 HP at 200 and 230 VAC and 5 HP at 460 and 575 VAC. This non-reversing NEMA motor starter has a melting alloy type overload relay that uses Type B thermal units to sense over current conditions. This NEMA starter has a 5 kA maximum SCCR (Short Circuit Current Rating) per UL508A when protected by an appropriate circuit breaker or fuse. Type S motor starters are available with replaceable coils in a wide variety of voltages. This starter has a 440/480 VAC 50/60 Hz operating coil wired for common control. This NEMA starter is in a NEMA 4 & 4X brushed stainless steel watertight and dusttight enclosure. This enclosure is 13.19 inches tall, 6.38 inches wide and 7.81 inches deep. A wide variety of accessories are available for Type S starters. This starter is supplied with a HOA selector switch and a red pilot light. Type S non-reversing NEMA motor starters are UL listed and CSA certified.
NEMA Motor Starter, Type S, nonreversing, Size 0, 18A, 5 HP at 460 VAC, 5 kA SCCR, 3 phase, 3 pole, melting alloy, 480 VAC coil, NEMA 4/4X
NEMA Motor Starter, Type S, nonreversing, Size 0, 18A, 5 HP at 460 VAC, 5 kA SCCR, 3 phase, 3 pole, melting alloy, 480 VAC coil, NEMA 4/4X
SKU: 15615442
Category: Starters & Contactors
Reviews (0)
Be the first to review “NEMA Motor Starter, Type S, nonreversing, Size 0, 18A, 5 HP at 460 VAC, 5 kA SCCR, 3 phase, 3 pole, melting alloy, 480 VAC coil, NEMA 4/4X” Cancel reply
Related products
Contactor TeSys LC1-K – 3 poles – AC-3 440V 9 A – coil 24 V AC
Contactor TeSys LC1-K - 3 poles - AC-3 440V 9 A - coil 24 V AC
Panelboard lighting contactor auxiliary contact module, top assembly, 1NO-1NC
Panelboard lighting contactor auxiliary contact module, top assembly, 1NO-1NC
TeSys D contactor – 4P(4 NO) – AC-1 – <= 440 V 60 A – 12 V DC standard coil
TeSys D contactor - 4P(4 NO) - AC-1 - <= 440 V 60 A - 12 V DC standard coil
Contactor, Type S, multipole lighting, mechanically held, 200A, 2 pole, 440/480 VAC 50/60 Hz coil, NEMA 12
Contactor, Type S, multipole lighting, mechanically held, 200A, 2 pole, 440/480 VAC 50/60 Hz coil, NEMA 12
Contactor, Type S, combination lighting, electrically held, 30A, 3 pole, breaker, 440/480 VAC 50/60 Hz coil, NEMA 1
Contactor, Type S, combination lighting, electrically held, 30A, 3 pole, breaker, 440/480 VAC 50/60 Hz coil, NEMA 1
Ambient Compensated Bimetallic Thermal Unit Class 20
Ambient Compensated Bimetallic Thermal Unit Class 20
Reviews
There are no reviews yet.