8903L multipole lighting contactors are for lighting control applications. 8903L lighting contactors are available in either mechanically held or electrically held versions. This is an electrically held device. Can switch up to 30 A fluorescent and 20 A tungsten lighting loads. The contacts are field convertible from NO to NC. This device 3 pole device has 3 NO contacts. Supplied with a 277 VAC 60 Hz interchangeable operating coil but other coils are available in a wide variety of common voltages up to 600VAC. Contactor is an open device. A variety of enclosure types are available. Coil and contacts are easily replaced. Lighting contactor is 5.00 inches tall, 2.88 inches wide and 3.12 inches deep. 8903L lighting contactors are UL Listed and CSA Certified.
Contactor, Type L, multipole lighting, electrically held, 30A, 3 pole, 600V, 277VAC 60Hz coil, open style
Contactor, Type L, multipole lighting, electrically held, 30A, 3 pole, 600V, 277VAC 60Hz coil, open style
SKU: 15612079
Category: Starters & Contactors
Reviews (0)
Be the first to review “Contactor, Type L, multipole lighting, electrically held, 30A, 3 pole, 600V, 277VAC 60Hz coil, open style” Cancel reply
Related products
IEC contactor, TeSys Deca, reversing, 25A, 15HP at 480VAC, 3 phase, 3 pole, 3 NO, 120VAC 50/60Hz coil, open style
IEC contactor, TeSys Deca, reversing, 25A, 15HP at 480VAC, 3 phase, 3 pole, 3 NO, 120VAC 50/60Hz coil, open style
Contactor, Type L, multipole lighting, mechanically held, 30A, 10 pole, 600 V, 277 VAC 60 Hz coil, NEMA 1, +option
Contactor, Type L, multipole lighting, mechanically held, 30A, 10 pole, 600 V, 277 VAC 60 Hz coil, NEMA 1, +option
NEMA Contactor, Type S, reversing, horizontal, Size 3, 90A, 50HP at 575VAC, 3 phase, up to 100kA, 3 pole, 120VAC coil, open style
NEMA Contactor, Type S, reversing, horizontal, Size 3, 90A, 50HP at 575VAC, 3 phase, up to 100kA, 3 pole, 120VAC coil, open style
TeSys D contactor – 4P(4 NO) – AC-1 – <= 440 V 80 A – 12 V AC 50 Hz coil
TeSys D contactor - 4P(4 NO) - AC-1 - <= 440 V 80 A - 12 V AC 50 Hz coil
TeSys D contactor – 4P(4 NO) – AC-1 – <= 440 V 60 A – 12 V DC standard coil
TeSys D contactor - 4P(4 NO) - AC-1 - <= 440 V 60 A - 12 V DC standard coil
TeSys GV7 Manual Starter and Protector, thermal magnetic circuit protector, rocker lever, 3 P, AC-3, 60…100 A, high interrupt
TeSys GV7 Manual Starter and Protector, thermal magnetic circuit protector, rocker lever, 3 P, AC-3, 60...100 A, high interrupt
Reviews
There are no reviews yet.