Type S non-reversing magnetic contactors are used to switch heating loads, capacitors, transformers, and electric motors where overload protection is provided separately. Type S contactors have ratings up to 810 amperes. This 2 pole NEMA Size 2 non-reversing contactor has a 45 ampere rating. Single phase NEMA Size 2 contactors have 3 HP at 115 VAC and 7.5 HP at 230 VAC ratings. This NEMA contactor has a 100 kA maximum SCCR rating per UL508A when protected by an appropriate circuit breaker or fuse. These contactors are available with replaceable coils in a wide variety of voltages. This contactor has a stronger 110/120 VAC 50/60 Hz coil that is wired for separate control. This NEMA contactor is an open device without an enclosure. This contactor is 5.13 inches tall, 5.63 inches wide and 4.94 inches deep. A wide variety of accessories are available for Type S contactors. This contactor is supplied with a Size 2 power pole with two normally closed contacts. Type S NEMA contactors are UL listed and CSA certified.
NEMA Contactor, Type S, nonreversing, Size 2, 45A, 7.5 HP at 230 VAC, 1 phase, up to 100 kA, 2 pole, 120 VAC coil, open
NEMA Contactor, Type S, nonreversing, Size 2, 45A, 7.5 HP at 230 VAC, 1 phase, up to 100 kA, 2 pole, 120 VAC coil, open
SKU: 4280822
Category: Starters & Contactors
Reviews (0)
Be the first to review “NEMA Contactor, Type S, nonreversing, Size 2, 45A, 7.5 HP at 230 VAC, 1 phase, up to 100 kA, 2 pole, 120 VAC coil, open” Cancel reply
Related products
NEMA Motor Starter, Type S, nonreversing, Size 3, 90A, 50 HP at 460 VAC, 5 kA SCCR, 2 phase, 4 pole, melting alloy, 240 VAC coil, NEMA 1
NEMA Motor Starter, Type S, nonreversing, Size 3, 90A, 50 HP at 460 VAC, 5 kA SCCR, 2 phase, 4 pole, melting alloy, 240 VAC coil, NEMA 1
Non-Reversing Contactor, Size 2, 2-Pole, Open Style +Options
Non-Reversing Contactor, Size 2, 2-Pole, Open Style +Options
IEC contactor, TeSys Deca, nonreversing, 32A, 20HP at 480VAC, 3 phase, 3 pole, 3 NO, 24VDC coil, open style
IEC contactor, TeSys Deca, nonreversing, 32A, 20HP at 480VAC, 3 phase, 3 pole, 3 NO, 24VDC coil, open style
Contactor, TeSys K, 3P, AC-3, lt or eq to 440V 9A, 1 NC aux., 24VAC coil
Contactor, TeSys K, 3P, AC-3, lt or eq to 440V 9A, 1 NC aux., 24VAC coil
Contactor, Type S, multipole lighting, mechanically held, 200A, 2 pole, 440/480 VAC 50/60 Hz coil, NEMA 12
Contactor, Type S, multipole lighting, mechanically held, 200A, 2 pole, 440/480 VAC 50/60 Hz coil, NEMA 12
Contactor, Type S, combination lighting, electrically held, 30A, 3 pole, breaker, 440/480 VAC 50/60 Hz coil, NEMA 1
Contactor, Type S, combination lighting, electrically held, 30A, 3 pole, breaker, 440/480 VAC 50/60 Hz coil, NEMA 1
Contactor, Type L, multipole lighting, mechanically held, 30A, 10 pole, 600 V, 277 VAC 60 Hz coil, NEMA 1, +option
Contactor, Type L, multipole lighting, mechanically held, 30A, 10 pole, 600 V, 277 VAC 60 Hz coil, NEMA 1, +option
Contactor, Type L, multipole lighting, mechanically held, 30A, 3 pole, 600 V, 110/120 VAC 50/60 Hz coil, NEMA 3R/12
Contactor, Type L, multipole lighting, mechanically held, 30A, 3 pole, 600 V, 110/120 VAC 50/60 Hz coil, NEMA 3R/12
Reviews
There are no reviews yet.