Type S NEMA motor starters are used for full voltage starting and stopping of AC squirrel cage motors. Type S motor starters have ratings up to 810 amperes. This 3 pole NEMA Size 0 non-reversing starter has an 18 ampere rating. This NEMA Size 0 motor starter has 3 phase ratings of 3 HP at 200 and 230 VAC and 5 HP at 460 and 575 VAC. This non-reversing NEMA motor starter has a melting alloy type overload relay that uses Type B thermal units to sense over current conditions. This NEMA starter has a 5 kA maximum SCCR (Short Circuit Current Rating) per UL508A when protected by an appropriate circuit breaker or fuse. Type S motor starters are available with replaceable coils in a wide variety of voltages. This starter has a 24 VAC 60 Hz operating coil wired for common control. A painted sheet steel NEMA 12/3R dusttight and driptight industrial use enclosure is used to protect this starter. Enclosure is 13.50 inches tall, 11.88 inches wide and 8.00 inches deep. A wide variety of accessories are available for Type S starters. This starter is supplied with fused transformer. Transformer has a 480 VAC primary and a 24 VAC secondary. This starter is also supplied with a HOA selector switch and a red pilot light. Type S NEMA starters are UL listed and CSA certified.
NEMA Motor Starter, Type S, nonreversing, Size 0, 18A, 5 HP at 460 VAC, 5 kA SCCR, 3 phase, 3 pole, melting alloy, 24 VAC coil, NEMA 12
NEMA Motor Starter, Type S, nonreversing, Size 0, 18A, 5 HP at 460 VAC, 5 kA SCCR, 3 phase, 3 pole, melting alloy, 24 VAC coil, NEMA 12
SKU: 16940494
Category: Starters & Contactors
Reviews (0)
Be the first to review “NEMA Motor Starter, Type S, nonreversing, Size 0, 18A, 5 HP at 460 VAC, 5 kA SCCR, 3 phase, 3 pole, melting alloy, 24 VAC coil, NEMA 12” Cancel reply
Related products
NEMA starter, Type S, reversing, vertical, Size 3, 90A, 50HP at 575VAC, 5kA SSCR, 3 phase, 3 pole, melting alloy overload, 120VAC coil, open
NEMA starter, Type S, reversing, vertical, Size 3, 90A, 50HP at 575VAC, 5kA SSCR, 3 phase, 3 pole, melting alloy overload, 120VAC coil, open
Contactor, Type S, multipole lighting, electrically held, 400A, 3 pole, 550/600 V 50/60 Hz coil, open style
Contactor, Type S, multipole lighting, electrically held, 400A, 3 pole, 550/600 V 50/60 Hz coil, open style
Contactor TeSys LC1-K – 3 poles – AC-3 440V 9 A – coil 24 V AC
Contactor TeSys LC1-K - 3 poles - AC-3 440V 9 A - coil 24 V AC
TeSys D contactor – 4P(4 NO) – AC-1 – <= 440 V 60 A – 12 V DC standard coil
TeSys D contactor - 4P(4 NO) - AC-1 - <= 440 V 60 A - 12 V DC standard coil
NEMA Contactor and NEMA Motor Starter, Type S, nonreversing, enclosure, NEMA Size 00, 0, 1, 8903SM lighting, NEMA 3R
NEMA Contactor and NEMA Motor Starter, Type S, nonreversing, enclosure, NEMA Size 00, 0, 1, 8903SM lighting, NEMA 3R
Reviews
There are no reviews yet.