Square D LA molded case circuit breakers provide thermal magnetic protection. Their primary function is automatic opening of a circuit under overload or short circuit conditions or manual opening. LH circuit breakers contain thermal (overload) and magnetic (short circuit) sensing elements in each pole. Push-to-Trip allows the circuit breaker to be manually tripped without exposure to live parts. This Square D LH molded case circuit breaker is a 2 pole unit I-Line breaker, 400A and 600VAC, with I-Line connection on line side and lugs on load side. The thermal magnetic circuit breaker has an interrupting rating of 25kA for 600VAC and 50kA for 250VDC with an AC phase connection. LH breakers are UL 489, CSA, IEC certified.
Circuit breaker, LH, 400A, 2 pole, 600VAC, 25kA, 250VDC, 50kA, I-Line, thermal magnetic, phase AC
Circuit breaker, LH, 400A, 2 pole, 600VAC, 25kA, 250VDC, 50kA, I-Line, thermal magnetic, phase AC
SKU: 1276019
Category: Circuit Breakers
Reviews (0)
Be the first to review “Circuit breaker, LH, 400A, 2 pole, 600VAC, 25kA, 250VDC, 50kA, I-Line, thermal magnetic, phase AC” Cancel reply
Related products
Mini circuit breaker, QO, 20A, 3 pole, 240VAC, 10kA, 100mA grd fault B, bolt on mount, ring
Mini circuit breaker, QO, 20A, 3 pole, 240VAC, 10kA, 100mA grd fault B, bolt on mount, ring
Circuit breaker, PowerPacT B, 60A, 1 pole, 600Y/347VAC, 25kA, lugs, thermal magnetic, 80%
Circuit breaker, PowerPacT B, 60A, 1 pole, 600Y/347VAC, 25kA, lugs, thermal magnetic, 80%
Circuit breaker, PowerPacT P, I-Line, Micrologic 5.0, 400A, 3 pole, 25kA, 600VAC, phase ABC, shunt trip, 80% rated
Circuit breaker, PowerPacT P, I-Line, Micrologic 5.0, 400A, 3 pole, 25kA, 600VAC, phase ABC, shunt trip, 80% rated
Motor circuit protector, PowerPacT H, unit mount, 30A, 3 pole, 25kA, 600 VAC, auxiliary switch, copper lugs, 80% rated
Motor circuit protector, PowerPacT H, unit mount, 30A, 3 pole, 25kA, 600 VAC, auxiliary switch, copper lugs, 80% rated
Circuit breaker, PowerPacT B, 30A, 3 pole, 600Y/347VAC, 14kA, lugs, thermal magnetic, 80%
Circuit breaker, PowerPacT B, 30A, 3 pole, 600Y/347VAC, 14kA, lugs, thermal magnetic, 80%
Circuit breaker, PowerPacT B, 15A, 3 pole, 600Y/347VAC, 14kA, I-Line, thermal magnetic, 80%, ABC
Circuit breaker, PowerPacT B, 15A, 3 pole, 600Y/347VAC, 14kA, I-Line, thermal magnetic, 80%, ABC
Circuit breaker frame, MasterPact MTZ2 32H2, 3200A, 100kA/440VAC 50/60Hz (Icu), 4P, drawout, without control unit
Circuit breaker frame, MasterPact MTZ2 32H2, 3200A, 100kA/440VAC 50/60Hz (Icu), 4P, drawout, without control unit
Second MX voltage release, MasterPact MTZ1 drawout, remote tripping, 277VAC 50/60Hz
Second MX voltage release, MasterPact MTZ1 drawout, remote tripping, 277VAC 50/60Hz
Reviews
There are no reviews yet.